OH What is an elevator?
In the elevator system, the OH (Overhead) part , also known as the space at the top of the elevator pit, is an extremely important factor that customers need to pay attention to when considering elevator installation. The height of the space at the top of the elevator will depend on the type of elevator and its speed, and a clear understanding of the factors that affect OH will help customers make better elevator installation decisions.
First, the elevator type will shape the OH. For example, high-speed elevators may require a larger OH space to ensure safety and performance. Conversely, low-speed elevators may require less OH space.
Second, the structure of the building also affects OH. Some buildings may have height constraints, reducing flexibility in designing elevator OH.
Finally, technical factors such as suspension and support structures also need to be considered. Advanced designs and technologies can help reduce OH space while ensuring elevator performance and safety.
Elevator OH height
The OH (Overhead) height of the elevator is an important factor that cannot be ignored during the installation and operation of the elevator. For a typical house, the floor height is usually between 3000mm and 3300mm. However, to ensure safety and optimal performance for elevators, experts generally recommend that the OH height should be maintained at 3800mm to 4200mm or more.
During the construction of new buildings, it is often easier to design and build the appropriate OH height for elevators, because you can calculate and adjust the necessary factors in advance. However, for renovations or townhouse projects, ensuring a qualified OH height can be more difficult due to space and structural constraints.
In this situation, flexibility and creativity in applying special elevator products and customized solutions are crucial. Using modern and flexible solutions will help optimize space and costs, while ensuring that elevators operate in the safest and most efficient way, in accordance with the specific requirements of each project. construction project.
Understanding the requirements and factors that influence OH height as well as finding flexible and effective solutions is important to ensure that the systemthang máyintegrated into the project in the most accurate and convenient way.
Why must there be a common standard for elevator OH?
Setting OH (Overhead) height standards in elevator systems is an indispensable part to ensure safety and performance of the equipment. OH plays an important role because this is where key components such as tractors, electrical cabinets, UPS rescue systems and other safety equipment are installed.
Ensuring OH meets standards will bring many benefits, including:
Guaranteed safety
Ensuring the safety of the elevator system is a top priority in design and operation. The OH (Overhead) height of the elevator plays an important role in ensuring safety for passengers and equipment, especially when the elevator operates on the highest floor.
When the elevator reaches the top floor, the OH height needs to ensure there is a large enough gap to avoid collision or conflict with accompanying equipment and accessories, such as the elevator cabin and safety system. This helps limit the risk of accidents in case the elevator operates unstable or overspeeds suddenly.
A height of about 3000mm is often considered to ensure sufficient space for equipment above the cabin roof. However, determining the specific OH height needs to comply with specific safety standards and technical regulations, appropriate to the specific elevator type and installation environment.
Equipment installation space
During the process of designing and installing elevators, determining the installation space for equipment is an important factor. In particular, at the first two sides of the elevator's journey, there is always a need for a travel limit system to ensure the safety of the elevator's movement.
However, if the elevator's OH height does not reach standard dimensions, this may affect the performance and accuracy of the travel limit system. When there is not enough space, sensors and travel limiters will not work effectively, leading to the risk of unwanted incidents during elevator operation.
Therefore, ensuring standard OH height is very important to ensure the safety and performance of the elevator system. Experts need to pay attention to determining and complying with installation space requirements to ensure stable and safe operation of elevators.
SEE MORE OTHER PRODUCTS:
Space for installation and maintenance:
During maintenance, repair and installation of equipment in the elevator system, having enough space is very important. Often, technicians will have to climb to the roof of the cabin or into the engine room to perform these operations. Therefore, increasing the OH height (distance from the ceiling of the building to the roof of the cabin) will bring convenience to the technician's access and operation.
When there is enough space, technicians can easily access and perform maintenance and repair of equipment without difficulty. This helps increase efficiency and accuracy during maintenance of the elevator system. Furthermore, having enough space also helps technicians work more safely and effectively, thereby ensuring stability and sustainability for elevator operations.
During maintenance, repair and installation of equipment in the elevator system, having enough space is very important. Often, technicians will have to climb to the roof of the cabin or into the engine room to perform these operations. Therefore, increasing the OH height (distance from the ceiling of the building to the roof of the cabin) will bring convenience to the technician's access and operation.
When there is enough space, technicians can easily access and perform maintenance and repair of equipment without difficulty. This helps increase efficiency and accuracy during maintenance of the elevator system. Furthermore, having enough space also helps technicians work more safely and effectively, thereby ensuring stability and sustainability for their operations.thang máy.
Factors affecting elevator OH
Factors affecting the OH height of an elevator are important conditions that need to be considered to ensure safe and efficient operation of the system. Here are the factors that need to be kept in mind:
Elevator travel speed : Elevator travel speed can affect the required OH height. When elevators operate at high speeds, the OH height requirement will also increase to ensure safety for passengers and goods.
Elevator installation location : Choosing the elevator installation location can affect the OH height. In some cases, installing elevators in older or completed homes may encounter difficulties with increasing the OH height due to space limitations.
Elevator manufacturing brand : Each elevator brand has different designs and sizes, so OH height requirements will also vary depending on the specific product. Choosing a reliable and experienced elevator brand will help ensure that the elevator system is properly designed and installed.
Buildings with low OH height: In the case of family buildings with low OH height, choosing a suitable and optimal elevator design will be very important. Careful consideration is required to ensure that the elevator is properly integrated into the space while still ensuring performance and safety.
Considering and properly meeting the above factors will help ensure that the elevator's OH height meets the correct safety and performance standards, while ensuring flexibility and space savings for the project. .
Compare elevator OH between elevators without machine room and elevators with machine room
The elevator has a machine room | Elevators do not have machine rooms | |
Concept | The OH (Overhead) height of an elevator with a machine room is measured from the floor of the top floor door to the highest point of the winch hanger on the roof of the machine room, including the tumulus containing the machine room. This is the distance from the highest point of the elevator car to the ceiling of the machine room, including auxiliary structures such as the winch hanger and the machine room tum. OH height determines the minimum height that the elevator machine room needs to have to ensure safety and efficient operation of the elevator. | The OH (Overhead) height of an elevator without a machine room is measured from the floor of the highest elevator door to the highest point of the elevator's top hoist hook. This is the distance from the highest point of the elevator car to the ceiling of the elevator floor, including the hoist suspension components and other structures on top of the elevator. The OH height is important to ensure free space above the elevator and enough space for the elevator car to move safely and efficiently. |
Characteristic | In addition to the standard height, there must be additional space for the engine room above. | Just need the top floor to reach the standard height according to each specific type of ladder |
OH height | The OH (Overhead Height) of an elevator with a machine room is calculated from the floor of the highest floor up to the floor where the elevator pulling machine is located. Normally, to ensure safe and efficient operation of the elevator, this OH height should reach 4200mm or more. At the same time, there needs to be a large enough space for the machine room, with a minimum height of 1,200mm or more. This helps ensure that the tractor equipment and other components have the necessary space and comfort to carry out future maintenance and repair activities. In this way, we not only optimize the usable space but also ensure the convenience and performance of the elevator during operation and maintenance. | The OH (Overhead Height) of an elevator without a machine room is calculated from the floor of the highest floor up to the ceiling of the elevator shaft, where the winch hanger is located. To ensure safe and efficient operation of the elevator, this OH height is usually recommended to be 4500mm or more. This size ensures that there is enough space for the elevator to move safely and conveniently. |
SEE MORE OTHER PRODUCTS: