Designing an elevator system is one of the extremely important steps because it determines whether the entire system, structure, components, and installation locations of parts are suitable for the elevator to operate smoothly or not. Are not.

Important Standards in Elevator Design

When designing an elevator system, you need to comply with the following standards so that the elevator operates stably and at the same time reduces problems and risks that arise later.

1. Elevator Safety Standards in Vietnam

This is one of the top standards that elevator companies and design engineers need to memorize, because it is not only related to legal regulations but also related to child safety. People.

Vietnam standard
Must Comply with Elevator Safety Standards in Vietnam

- Vietnamese standard TCVN 5866:1995 Elevators - Mechanical safety structure
- Vietnamese standard TCVN 5744:1993 Elevators - Safety requirements in installation and use
- Vietnamese standard TCVN 6904:2001 on Electric elevators - Test methods
(Safety requirements for structure and installation)
- Vietnamese standard TCVN 6905: 2001 Hydraulic elevators
- Vietnamese standard TCVN 6396-28:2013 Structural safety requirements Creating and installing elevators
(Elevators carrying people and goods)
- Vietnamese standard TCVN 6395:2008 Electric elevators
(Safety requirements for structure and installation)

installation process
Elevator installation process - Sankyo Elevator

2. Standards for Size and Load of Elevators

For high-rise buildings with low/medium height up to 15 floors, they usually have a load capacity of 320 - 1000kg and a cabin height of 2200mm for passenger elevators. Particularly for specialized elevators, the load can be up to 2000kg. This is regulated according to national standard TCVN 7628-1: 2007 on elevator installation.

standard cabin size
Standards for Size and Load of Elevators

3. Standards for Elevator Density in High-Rise Buildings

According to national standards QCVN 04:2018/BXD, regulations on apartment buildings are clearly specified.

Apartment buildings with 6 floors or more: Minimum 1 elevator.
Apartment buildings with 9 floors or more: Minimum 2 months of computer.
In addition, at least 1 elevator must have a clear size that can transport an emergency stretcher.

The condition of the carpet is due to the elevator
Elevator Density Standards

Install 1 elevator calculated based on the population density of 250 people (About 64 apartments) and excluding the number of people on the first floor. The minimum elevator load is 400kg, if there is only one elevator, the load Minimum from 600kg.


4. Standards for Elevator Installation Location

Currently in Vietnam there are no specific regulations on the location of elevator installation, however, for convenience in moving, repairing, maintaining, renovating elevators and also for aesthetics, elevators should be placed. machine next to the stairs or inside the stairs.
See Now: Elevator Size, Elevator Installation Location According to Feng Shui

elevator location
Elevator Installation Location

5. Engine Room Construction Standards

Current elevator systems are divided into two types: with machine room and without machine room . Please refer to the design drawings of both types of systems.

The elevator has a machine room
Elevator with machine room - Sankyo Elevator
elevator counterweight
Elevator counterweight with machine room - Sankyo Elevator
The elevator does not have a machine room
Elevator without machine room - Sankyo Elevator

Choosing Suitable Elevator Components and Models

For imported elevators, they are manufactured according to process and quality inspection before being imported to Vietnam, so you can rest assured about the components in the elevator system, but the price will be very expensive, due to the incur additional import fees. As for joint venture elevators manufactured from domestic and foreign components, costs will be greatly reduced while still ensuring quality standards for use in Vietnam.

elevator company
SANKYO Elevator elevator company

Elevator Components

If customers choose joint venture elevator products, they should consider choosing a reputable, quality elevator supplier or elevator company to ensure the system operates stably, safely and efficiently. Maintenance is also more convenient.
See more: What is a joint venture elevator? Quality elevator company in Vietnam
Some typical components in the elevator system:

1. Components of the Operating System:

Components in the operating system are imported directly from abroad by Sankyo Elevator.

elevator traction machine
Types of elevator traction machines - Sankyo Elevator
elevator electrical cabinet
Types of elevator electrical cabinets - Sankyo Elevator
elevator door head
Sankyo Elevator - Sankyo Elevator
elevator rope
Some types of wires used in elevators - Sankyo Elevator

2. Components in Elevator Cabin

The components in the elevator cabin also play a very important role, because they represent the nature of the surrounding environment, the user's personal style and aesthetics. Some components in elevator cabins are being produced and widely used on the market today:

elevator pattern
Pattern for elevator doors - Sankyo Elevator

false ceiling
False ceiling for elevator - Sankyo Elevator
Elevator button
Elevator buttons - Sankyo Elevator

See Now: Full range of elevator components and prices

Elevator System Installation Process At Sankyo Elevator

installation process
Elevator installation process - Sankyo Elevator

SANKYO ELEVATOR - LEADING PRESTIGIOUS ELEVATOR COMPANY IN VIETNAM

Consulting Specialist: 0907. 090. 551
Head Office:
184/20 Le Dinh Can, Tan Tao Ward, City. HCM
Hanoi headquarters: No. 229, D. Van Tri, Van Noi, Dong Anh, Hanoi
Website : hoangsaviet.net Email: hungpham@hoangsaviet.com

0707.025.789